Troubleshooting and diagnosing their problems.
Hayward aqua rite salt chlorine generator troubleshooting.
If the incorrect cell is chosen the salt level will be inaccurate and the system will likely suspend chlorination as a result.
Start with the main toggle switch in the auto position.
Well the good news is you are at the right spot and you re definitely not alone.
Aquarite turns salt into chlorine eliminating red eyes itchy skin harsh odors.
Before operation the aquarite must be configured to the correct turbocell installed.
Just like any other salt chlorine generator the aqua rite may need a quick tune up from time to time.
Check salt inspect cell.
If the incorrect cell is chosen the salt level amperage and voltage will not be correct and the system will turn the chlorinator off.
Check salt inspect cell.
Using information provided by hayward pool we have created the following troubleshooting guide to help pool owners understand the diagnostic codes and quickly restore their hayward aqua rite salt chlorination system.
Salt chlorine generators are great products.
Before operation the aqua rite must be configured for the chlorinator cell that will be used.
The hayward aqua rite salt chlorine generator is hands down the most popular residential salt chlorinator in the pool industry.
Aquarite the world s 1 salt chlorinator delivers soft silky water.
After you inspect the cell and.
Check salt inspect cell.
Make sure you have at least 12 of straight pipe before the flow switch.
Slide the main switch to the auto position.
Flashing or on 1.
Clean if necessary press the small diagnostic button next to the display for 3 seconds to stop.
Hayward aqua rite troubleshooting guide.
T is the factory default.
But you know what s not great.
The aqua rite electrolytic cell has a self cleaning feature incorporated into the electronic control s.
If the check salt inspect cell leds cleared then the problem is solved.
This does not affect chlorine production.
The hayward aqua rite has sensed a no flow condition and has stopped generating chlorine.
Check that the flow switch is plugged into the connector on the bottom of the control unit and that the wire is not cut or damaged.
T 15 is the factory default.
The flashing inspect cell led and start the timer for the next 500 hours.
Flashing or on cont 18 the cell needs to be replaced in order for the aquarite control center to read the salt level accurately.
If you re reading this blog that means you need help troubleshooting your hayward aqua rite salt system.